Hanna HI 98703 Portable Turbidity Meter (Nephelometer)

Location: Ontario, CA
Condition: New
Manufacturer: HANNA Instruments
Model: HI 98703
Warranty: Yes
Categories: Turbidity Meters

Original price was: $1,000.00.Current price is: $999.00.

The HI 98703 portable Turbidity Meter utilizes an EPA compliant tungsten light source and state-of-the-art optical system that allows consistently reliable and accurate measurements for turbidity. Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels. To meet EPA reporting requirements these instruments have an EPA compliance reading mode. HI 98703 meets all EPA requirements with regards to the Standard Methods for Turbidity Measurements. It meets and exceeds the requirements of the USEPA Method 180.1 for wastewater and Standard Method 2130 B for drinking water. Depending on the measured sample and required accuracy, users can select normal measurement, continuous measurement or signal averaging. HI 98703 can be equipped with the (optional) Tag Identification System (TIS) which allows users to record the time and location of a specific measurement or series of measurements. Logged data can be downloaded to a PC through either USB or RS232 connections. Reliable performance of the instrument is validated using the meters’ Cal Check system and NiST traceable chlorine standards. For turbidity, a two, three or four-point calibration is available using pre-set or user defined standards. Frequent Calibration isn’t necessary as the system compensates for variations in the intensity of the light source. The instruments’ Good Laboratory Practice functions allow traceability of calibration conditions including the time, date and last calibration points. At startup, the meter displays the percentage of remaining battery life. A ‘low battery’ warning message is also displayed on the LCD to avoid unexpected battery failure. This instrument is equipped with backlighting. The current date and time can be displayed on the LCD.
Range: 0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
Range Selection: Automatic
Resolution: 0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
Accuracy: ±2% of reading plus 0.02 NTU
Repeatability: ±1% of reading or 0.02 NTU, whichever is greater
Light Detection: Silicon Photocell
Method: Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B.
Measuring mode: Normal, Average, Continuous
Turbidity Standards: 1, 10, 100 and 750 NTU
Calibration: Two, three or four-point calibration
Light Source: Tungsten filament lamp
Lamp life: Greater than 100,000 readings
Logging Memory: 200 records
The following link provides additional information from the manufacturer’s brochure. Click to open the PDF in a new window or right-click to download it:
Hanna HI 98703 Portable Turbidity Meter or copy the following into your browser address window: labequip.com/stock/pictures/n728.pdf

ACCESSORIES:

COMES COMPLETE WITH:
(5) sample cuvets and caps
HI 98703-11 calibration cuvets
HI 93703-58 silicone oil
cuvet wiping tissue
(4) batteries
AC adapter
instruction manual
rugged carrying case

OPTIONAL ACCESSORIES AVAILABLE AT ADDITIONAL COST:
HI 920005 Tag holders with tags (5)
HI 98703-58 Silicone oil (15 mL)
HI 93703-60 Caps for cuvets (4)
HI 731318 Tissue for wiping cuvets (4)
HI 731331 Glass cuvets (4)
HI 92000 Windows® compatible software
HI 920011 5 to 9 pin RS232 connection cable
HI 920013 USB cable for PC connection
HI 98703-11 Turbidity standards kit
HI 93703-50 Cuvet cleaning solution, 250 mL

Shipping Information

Location: Ontario, CA

 



Return Policy:

WARRANTY AND RETURN POLICY: All instruments are covered by the full manufacturers warranty. Returns are accepted at the discretion of the manufacturer, and may incur a restocking fee. Shipping and handling fees are not refundable. Damage in shipping must be reported within 24 hours to the shipping company and to Labequip. If the box is damaged on delivery, be sure to note the damage on the bill of lading before signing for receipt.

Our continued success in business for over 40 years is based on our commitment to total customer satisfaction. We will try our best to resolve any reasonable complaints. Please contact us as soon as possible after receipt of the item if there is anything that is not to your satisfaction.

CURRENCY: All prices on LabX are in US dollars.

HOURS: Monday-Friday 9-4:30 Eastern time. We are not open to the public. Your e-mail will be answered as soon as possible. SHIPPING AND TERMS OF PAYMENT: Payment are wire transfer, email transfer or credit card (under $3000) at time of invoicing. We strive to ship ordersas quickly as possible, but this is dependent on lead times from manufactueres. We do not ship COD, third-party billing, or to PO boxes. Please ask for a quote on shipping, which will include customs and brokerage charges within Canada, and mandatory insurance. Net 30 terms are only granted to universities, governments, and public hospitals. For deliveries to California and Canada, we are required by law to collect sales tax as applicable.

OUTSIDE THE US AND CANADA, TERMS OF PAYMENT AND SHIPPING: Payment is by bank wire transfer only. Before purchasing, please take into account the shipping charges, and all taxes/duties charged by your home country.

Labequip.com

Ontario, CA

LabX Member Since December 27th, 1997

 

Founded in 1974, Labequip is committed to providing the scientific community with the highest quality laboratory instruments and equipment at the lowest possible price. By remaining focused on that goal, our business has grown steadily, today serving all types of organizations and industries worldwide. We offer a complete line of top quality new instruments, representing top brands like Lovibond (Tintometer), Koehler, Byk Gardner, Bransonic, IKA, Labconco, Shel-Lab, Tuttnauer and many others.

Reviews

There are no reviews yet.

Be the first to review “Hanna HI 98703 Portable Turbidity Meter (Nephelometer)”

Your email address will not be published. Required fields are marked *

Scroll to Top